INSPECTION & RECERTIFICATION: FLOW CONTROL SERVICES
Coil Solutions Inc provides inspection and recertification flow control services for all high pressure surface piping that is used in pressure pumping operations. These applications include nitrogen pumping, fluid pumping, fracing, cementing and production testing (flow back). The published minimum requirement is a level 1 inspection annually. Customers may choose to have level 2 or 3 inspections done to provide additional confidence in equipment safety.
Levels of High Pressure Iron Inspection
Level 1-
Level 2-
Level 3-
Read original source: http://www.coilsolutions.com/services/inspection-recertification/flow-control/
Levels of High Pressure Iron Inspection
Level 1-
- Visual Inspection
- Ultra Sonic Wall Thickness
- Remove wings
- Magnetic Particle Inspection
- Install Stainless Steel ID Banding
Level 2-
- Visual Inspection
- Ultra Sonic Wall Thickness
- Remove wings
- Sand Blast
- Magnetic Particle Inspection
- Pressure Test
- Paint
- Install Stainless Steel ID Banding
Level 3-
- Visual Inspection
- Ultra Sonic Wall Thickness
- Remove wings
- Sand Blast
- Rebuild
- Magnetic Particle Inspection
- Pressure Test
- Paint
- Install Stainless Steel ID Banding